InTech Innovator's Award 2009
Senscient ELDS™ open path gas detection (OPGD) products
Download an ELDS Field Evaluation Report
Products

Senscient ELDS™ Open Path Gas Detectors (OPGD)

ELDS™ is a patented, new open path gas detection (OPGD) technology from Senscient. The innovative Enhanced Laser Diode Spectroscopy (ELDS) detection technology featured in our ELDS Series of open path gas detectors truly fulfills the promise of fit-and-forget open path gas detection...

  • Reliable detection of both toxic & flammable gases.
  • Industry’s first false-alarm free Open Path Gas Detector. ELDS detection is molecular species specific, eliminating false alarms from common atmospheric or non-hazardous gases that plague traditional OPGD (or any NDIR or LDS technology) systems.
  • FIRST and ONLY laser open path combustible gas detector to meet current industry Safety and Performance Standards.
  • FIRST and ONLY gas detector with SimuGas™, an electronic, remote functionality check.
  • 3 orders of magnitude greater sensitivity for combustible gases versus conventional NDIR-based detectors.
  • Up to 60% reduction in gas detection project CapEx and OpEx, with true Fit-&-Forget functionality.
  • Backed by a network of industry-leading gas detection solutions providers.

Product Shortcuts:


EX FM Approval
EX FM Approval
Senscient ELDS OPGD Series 2000 H2S+CH4 Detector

  • Reliable, open path detection of both methane and hydrogen sulfide in a single unit.
  • Faster response than any other hydrogen sulfide detection technology.
  • No need to replace or re-calibrate sensors.
  • No false alarms from any other gases including diesel fumes or oil mist.
  • True ease-of-installation, with vibration and misalignment tolerant optics.
  • SimuGas™ feature provides ability to accomplish on-demand, remote functionality testing right from the control room or PLC!
  • 316L Stainless steel construction designed to provide maximum corrosion resistance for installation in sea and land-based Hazardous Area facilities.

Applications:

Offshore Platforms, FPSO’s, Onshore Petrochemical facilities and Refineries.

Theory of Operation:

Using a separate transmitter and receiver configuration, Senscient ELDS Series 2000 H2S+CH4 OPGD systems can detect and measure methane and hydrogen sulfide over distances between 5 and 60 m. The ELDS technique measures the Harmonic Fingerprint introduced onto the transmitter’s laser beam(s) by absorption by any target gas in the monitored path.

In the vast majority of instances, hydrogen sulfide is found as a component of the solution gas or natural gas present at the facility, intimately mixed with predominantly methane. When solution gas or natural gas containing hydrogen sulfide leaks, its components do not separate regardless of the density of the individual gases. It remains intimately mixed and the hydrogen sulfide follows the same leak path as the rest of the gas.

Download Senscient ELDS™ Series 2000 H2S+CH4 Open Path Gas Detector Product Data Sheet

Return to the top of this page Return To Top of Page


EX FM Approval
EX FM Approval
Senscient ELDS OPGD Series 2000 H2S Hydrogen Sulfide Detector

  • Reliable, open path detection of hydrogen sulfide at levels low enough to protect personnel from the toxic hazard.
  • Faster response than any other hydrogen sulfide detection technology.
  • No need to replace or re-calibrate sensors.
  • True ease-of-installation, with vibration and misalignment tolerant optics.
  • SimuGas™ feature provides ability to accomplish on-demand, remote functionality testing right from the control room or PLC!
  • 316L Stainless steel construction designed to provide maximum corrosion resistance for installation in sea and land-based Hazardous Area facilities.

Applications:

Offshore Platforms, FPSO’s, Onshore Petrochemical facilities and Refineries.

Theory of Operation:

Using a separate transmitter and receiver configuration, Senscient ELDS Series 2000 H2S OPGD systems can detect and measure hydrogen sulfide over distances between 5 and 60 m. The ELDS technique measures the Harmonic Fingerprint introduced onto the transmitter’s laser beam(s) by absorption by any target gas in the monitored path.

Download Senscient ELDS™ Series 2000 H2S Hydrogen Sulfide Open Path Gas Detector Product Data Sheet

Return to the top of this page Return To Top of Page


EX FM Approval
EX FM Approval
Senscient ELDS OPGD Series 1000 Methane Detector

  • Reliable, open path detection of methane at levels low enough to provide early warning for leakage of this highly flammable gas. Detection Limits for methane leak detection are orders of magnitude lower than any other OPGD product.
  • No false alarms from any other hydrocarbon gases including diesel fumes or oil mist.
  • True ease-of-installation, with vibration and misalignment tolerant optics.
  • SimuGas™ feature provides ability to accomplish on-demand, remote functionality testing right from the control room or PLC!
  • 316L Stainless steel construction designed to provide maximum corrosion resistance for installation in sea and land-based Hazardous Area facilities.

Applications:

Offshore Platforms, FPSO’s, Onshore Petrochemical facilities and Refineries.

Theory of Operation:

Using a separate transmitter and receiver configuration, Senscient ELDS Series 1000 Methane OPGD systems can detect and measure methane over line of sight distances between 5 and 200 m. The ELDS technique measures the Harmonic Fingerprint introduced onto the transmitter’s laser beam(s) by absorption by any target gas in the monitored path.

Download Senscient ELDS™ Series 1000 CH4 Methane Open Path Gas Detector Product Data Sheet

Return to the top of this page Return To Top of Page


EX FM Approval
EX FM Approval
Senscient ELDS OPGD Series 1000 Propane Detector

  • Reliable, open path detection of propane at levels low enough to provide early warning for leakage of this highly flammable gas. Detection Limits for propane leak detection are orders of magnitude lower than any other OPGD product.
  • No false alarms from any other hydrocarbon gases including diesel fumes or oil mist.
  • True ease-of-installation, with vibration and misalignment tolerant optics.
  • SimuGas™ feature provides ability to accomplish on-demand, remote functionality testing right from the control room or PLC!
  • 316L Stainless steel construction designed to provide maximum corrosion resistance for installation in sea and land-based Hazardous Area facilities.

Applications:

Onshore Petrochemical and mid-industrial facilities and Refineries.

Theory of Operation:

Using a separate transmitter and receiver configuration, Senscient ELDS Series 1000 Propane OPGD systems can detect and measure propane over distances between 5 and 200 m. The ELDS technique measures the Harmonic Fingerprint introduced onto the transmitter’s laser beam(s) by absorption by any target gas in the monitored path.

Download Senscient ELDS™ Series 1000 Propane Open Path Gas Detector Product Data Sheet

Return to the top of this page Return To Top of Page


EX FM Approval
EX FM Approval
Senscient ELDS OPGD Series 1000 Butane Detector

  • Reliable, open path detection of Butane at levels low enough to provide early warning for leakage of this highly flammable gas. Detection Limits for Butane leak detection are orders of magnitude lower than any other OPGD product.
  • No false alarms from any other hydrocarbon gases including diesel fumes or oil mist.
  • True ease-of-installation, with vibration and misalignment tolerant optics.
  • SimuGas™ feature provides ability to accomplish on-demand, remote functionality testing right from the control room or PLC!
  • 316L Stainless steel construction designed to provide maximum corrosion resistance for installation in sea and land-based Hazardous Area facilities.

Applications:

Onshore Petrochemical and mid-industrial facilities and Refineries.

Theory of Operation:

Using a separate transmitter and receiver configuration, Senscient ELDS Series 1000 Butane OPGD systems can detect and measure Butane over distances between 5 and 200 m. The ELDS technique measures the Harmonic Fingerprint introduced onto the transmitter’s laser beam(s) by absorption by any target gas in the monitored path.

Download Senscient ELDS™ Series 1000 Butane Open Path Gas Detector Product Data Sheet

Return to the top of this page Return To Top of Page


EX FM Approval
EX FM Approval
Senscient ELDS OPGD Series 1000 XD Cross Duct & HVAC Methane Detector

  • Reliable, rapid detection of methane at the lowest levels required for cross-duct and HVAC applications.
  • 100% continuous measurement of the amount of gas in the duct enables rapid detection of gas without the false-alarms associated with systems that make measurement flashes just a few times a second.
  • Fully heated optics and no retroreflector means no problems with condensation or hoar frost.
  • No false alarms from any other hydrocarbon gases including diesel fumes or oil mist.
  • True ease-of-installation, with vibration and misalignment tolerant optics.
  • SimuGas™ feature provides ability to accomplish on-demand, remote functionality testing right from the control room or PLC.
  • 316L Stainless steel construction designed to provide maximum corrosion resistance for installation in sea and land-based Hazardous Area facilities.

Applications:

HVAC ducts, turbine inlets, turbine acoustic enclosures.

Theory of Operation:

Using a separate transmitter and receiver configuration, Senscient ELDS Series 1000 XD Cross Duct & HVAC OPGD systems can detect and measure methane in ducts between 0.5 m and 5 m wide.  The ELDS technique measures the Harmonic Fingerprint introduced onto the transmitter’s laser beam(s) by absorption by any target gas in the unit’s path.

Download Senscient ELDS™ Series 1000 XD Open Path Gas Detector Product Data Sheet

Return to the top of this page Return To Top of Page


EX FM Approval
EX FM Approval
Senscient ELDS OPGD Series 1000 XC Coal Bed Methane Detector

  • Reliable, rapid detectionof methane concentrations in pre-combustion ventilation systems at 0.5 to 5.0 meters.
  • 100% continuous measurement of normal gas levels present in the combustion stream and rapid, accurate detection of breakthrough gas levels for optimum safety in combustion operations.
  • Fully heated optics and no retroreflector panels in the duct eliminates interference from condensation and moisture in the gas stream.
  • No false alarms from any other hydrocarbon gases including ethane diesel fumes or oil mist.
  • True ease-of-installation, with vibration and misalignment tolerant optics.
  • SimuGas™ feature provides ability to accomplish on-demand, remote functionality testing right from the control room or PLC.
  • 316L Stainless steel construction designed to provide maximum corrosion resistance for installation in sea and land-based Hazardous Area facilities.

Applications:

Coal mine ventilation, combustion systems.

Theory of Operation:

Using a separate transmitter and receiver configuration, Senscient ELDS Series 1000 XC Coal Bed Combustion OPGD systems can detect and measure methane across distances between 0.5 m and 5 m wide. The ELDS technique measures the Harmonic Fingerprint introduced onto the transmitter's laser beam(s) by absorption of methane gas in the unit's path.

In coal bed methane combustion applications, it is anticipated that there will always be a significant %LEL of methane in the flow path. The ELDS Series 1000 XC very rapidly responds to any change in the concentration of methane in the combustion stream. This application for pre-combustion monitoring differs from the typical personnel safety application for HVAC ducts where the system is tasked with detecting the first and sudden appearance of low levels of methane in an HVAC duct that should normally contain only air.

Download Senscient ELDS™ Series 1000 XC Coal Bed Methane Detector Product Data Sheet

Return to the top of this page Return To Top of Page


EX FM Approval
EX FM Approval
Senscient ELDS OPGD Series 1000 Ammonia

  • Reliable, open path detection of ammonia at levels low enough to provide early warning for leakage of this highly toxic gas. Detection Limits for ammonia leak detection are orders of magnitude lower than any other OPGD product.
  • Specific detection of Ammonia without any cross interference from any other gases virtually eliminates false alarms.
  • True ease-of-installation, with vibration and misalignment tolerant optics.
  • SimuGas™ feature provides ability to accomplish on-demand, remote functionality testing right from the control room or PLC!
  • 316L Stainless steel construction designed to provide maximum corrosion resistance for installation in sea and land-based Hazardous Area facilities.

Applications:

Onshore Petrochemical, Pharmaceutical, Agricultural, Industrial Refrigerants and mid-industrial facilities.

Theory of Operation:

Using a separate transmitter and receiver configuration, Senscient ELDS Series 1000 Ammonia OPGD systems can detect and measure ammonia over distances between 5 and 120 m. The ELDS technique measures the Harmonic Fingerprint introduced onto the transmitter’s laser beam(s) by absorption by any target gas in the monitored path.

Download Senscient ELDS™ Series 1000 Ammonia Product Data Sheet

Return to the top of this page Return To Top of Page


EX FM Approval
EX FM Approval
Senscient ELDS OPGD Series 1000 Carbon Dioxide

  • Reliable, open path detection of carbon dioxide at levels low enough to provide early warning for leakage of this highly toxic gas. Detection Limits for carbon dioxide leak detection are orders of magnitude lower than any other OPGD product.
  • Specific detection of Carbon Dioxide without any cross interference from any other gases virtually eliminates false alarms.
  • True ease-of-installation, with vibration and misalignment tolerant optics.
  • SimuGas™ feature provides ability to accomplish on-demand, remote functionality testing right from the control room or PLC!
  • 316L Stainless steel construction designed to provide maximum corrosion resistance for installation in sea and land-based Hazardous Area facilities.

Applications:

Offshore and Onshore Petrochemical, Pharmaceutical and mid-industrial facilities.

Theory of Operation:

Using a separate transmitter and receiver configuration, Senscient ELDS Series 1000 Carbon Dioxide OPGD systems can detect and measure carbon dioxide over distances between 5 and 200 m. The ELDS technique measures the Harmonic Fingerprint introduced onto the transmitter’s laser beam(s) by absorption by any target gas in the monitored path.

Download Senscient ELDS™ Series 1000 Carbon Dioxide Product Data Sheet

Return to the top of this page Return To Top of Page


EX FM Approval
EX FM Approval
Senscient ELDS OPGD Series 1000 Ethylene

  • Reliable, open path detection of ethylene at levels low enough to provide early warning for leakage of this highly flammable gas. Detection Limits for ethylene leak detection are orders of magnitude lower than any other OPGD product.
  • Specific detection of Ethylene without any cross interference from any other gases virtually eliminates false alarms.
  • True ease-of-installation, with vibration and misalignment tolerant optics.
  • SimuGas™ feature provides ability to accomplish on-demand, remote functionality testing right from the control room or PLC!
  • 316L Stainless steel construction designed to provide maximum corrosion resistance for installation in sea and land-based Hazardous Area facilities.

Applications:

Onshore Petrochemical, Textile and mid-industrial facilities.

Theory of Operation:

Using a separate transmitter and receiver configuration, Senscient ELDS Series 1000 Ethylene OPGD systems can detect and measure ethylene over distances between 5 and 200 m. The ELDS technique measures the Harmonic Fingerprint introduced onto the transmitter’s laser beam(s) by absorption by any target gas in the monitored path.

Download Senscient ELDS™ Series 1000 Ethylene Product Data Sheet

Return to the top of this page Return To Top of Page


EX FM Approval
EX FM Approval
Senscient ELDS OPGD Series 1000 Hydrogen Chloride

  • Reliable, open path detection of hydrogen chloride at levels low enough to provide early warning for leakage of this highly toxic gas. Detection Limits for hydrogen chloride leak detection are orders of magnitude lower than any other OPGD product.
  • Specific detection of Hydrogen Chloride without any cross interference from any other gases virtually eliminates false alarms.
  • True ease-of-installation, with vibration and misalignment tolerant optics.
  • SimuGas™ feature provides ability to accomplish on-demand, remote functionality testing right from the control room or PLC!
  • 316L Stainless steel construction designed to provide maximum corrosion resistance for installation in sea and land-based Hazardous Area facilities.

Applications:

Onshore Petrochemical.

Theory of Operation:

Using a separate transmitter and receiver configuration, Senscient ELDS Series 1000 Hydrogen Chloride OPGD systems can detect and measure hydrogen chloride over distances between 5 and 60 m. The ELDS technique measures the Harmonic Fingerprint introduced onto the transmitter’s laser beam(s) by absorption by any target gas in the monitored path.

Download Senscient ELDS™ Series 1000 Hydrogen Chloride Product Data Sheet

Return to the top of this page Return To Top of Page


EX FM Approval
EX FM Approval
Senscient ELDS OPGD Series 1000 Hydrogen Fluoride

  • Reliable, open path detection of hydrogen fluoride at levels low enough to provide early warning for leakage of this toxic gas. Detection Limits for hydrogen fluoride leak detection are orders of magnitude lower than any other OPGD product.
  • Specific detection of Hydrogen Fluoride without any cross interference from any other gases virtually eliminates false alarms.
  • True ease-of-installation, with vibration and misalignment tolerant optics.
  • SimuGas™ feature provides ability to accomplish on-demand, remote functionality testing right from the control room or PLC!
  • 316L Stainless steel construction designed to provide maximum corrosion resistance for installation in sea and land-based Hazardous Area facilities.

Applications:

Onshore Petrochemical, Pharmaceutical and mid-industrial facilities.

Theory of Operation:

Using a separate transmitter and receiver configuration, Senscient ELDS Series 1000 Hydrogen Fluoride OPGD systems can detect and measure hydrogen fluoride over distances between 5 and 60 m. The ELDS technique measures the Harmonic Fingerprint introduced onto the transmitter’s laser beam(s) by absorption by any target gas in the monitored path.

Download Senscient ELDS™ Series 1000 Hydrogen Fluoride Product Data Sheet

Return to the top of this page Return To Top of Page


EX FM Approval
EX FM Approval
Senscient ELDS OPGD Series 1000 LT Methane Detector

  • High grade aluminum construction suitable for installation in land based indoor/outdoor Hazardous Area facilities.
  • Reliable, open path detection of methane at levels low enough to provide early warning for leakage of this highly flammable gas. Detection Limits for methane leak detection are orders of magnitude lower than any other OPGD product.
  • No false alarms from any other hydrocarbon gases including diesel fumes or oil mist.
  • True ease-of-installation, with vibration and misalignment tolerant optics.
  • SimuGas™ feature provides ability to accomplish on-demand, remote functionality testing right from the control room or PLC!

Applications:

Onshore Petrochemical and mid-industrial facilities and Refineries.

Theory of Operation:

Using a separate transmitter and receiver configuration, Senscient ELDS Series 1000 LT Methane OPGD systems can detect and measure methane over distances between 5 and 200 m. The ELDS technique measures the Harmonic Fingerprint introduced onto the transmitter’s laser beam(s) by absorption by any target gas in the monitored path.

Download Senscient ELDS™ Series 1000 LT Methane Detector Product Data Sheet

Return to the top of this page Return To Top of Page


 

Senscient introduces affordable, reliable, line-of-sight flammable and toxic gas detection utilizing
revolutionary
Enhanced Laser Diode Spectroscopy (ELDS™)

"… SimuGas™ feature insures optimum safety system integrity…"

"…multi-gas capability saves project capital costs…"

"… virtually no cost-of-ownership…"